D-Link DES-1008PA Betriebsanweisung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
PoE MAX
Green
When the power output to PDs is over 42W. No additional PDs can be
powered.
Off When the system is using less than 42W
Blinking
Green
After the power output to PDs has reached or exceeded the maximum
power budget, if the user unplugged certain PDs and made the system
power left over 10W, the PoE MAX will blink 2 minutes.
Ethernet port status LEDs (Ports 1~8)
10/100M Link/ACT:
10M :
When the 10M LED lights on, the respective port is successfully
connected to 10M Ethernet network. Otherwise, when the 10M LED is
blinking, the port is transmitting or receiving data on the Ethernet
network.
100M :
When the 100M LED lights on, the respective port is successfully
connected to 100M Fast Ethernet network. Otherwise, when the 100M
LED is blinking, the port is transmitting or receiving data on the Fast
Ethernet network.
Off : No link.
PoE Rule
POE M ax: this function will help to protect the POE Switch and to
stabilize the power transmitting to the powered device (PD).
If the system power usage is >= 42, the POE MAX LED will turn on
and the system will not provide power to the additional POE PD. This
is done to protect the POE Switch itself and to stabilize the power
transmitting to the other POE PDs plugged into the Switch.