©Copyright 2009. All rights reservedUser ManualProduct Model: DAS-3626VDSL2 SwitchRelease 1.00
DAS-3626 VDSL2 Switch User Manual System Save MenusThe web interface for the switch includes two drop-down menus, the Save and Tools menus, located ju
DAS-3626 VDSL2 Switch User Manual Figure 120. Access Profile Details (Packet Content)To return to the CPU Access Profile List click Show All Profiles
DAS-3626 VDSL2 Switch User Manual The following parameters may be configured for the Packet Content filter.Parameter Descriptio
DAS-3626 VDSL2 Switch User Manual NOTE: Address Resolution Protocol (ARP) is the standard for finding a host's hardware address (MAC Address). H
DAS-3626 VDSL2 Switch User Manual Section 9VLANManagement VLANThe 802.1Q VLAN window lists all previously configured VLANs by VLAN ID and VLAN Name. T
DAS-3626 VDSL2 Switch User Manual Figure 126. 802.1Q VLAN menu – Add/Edit VLAN TabTo return to the 802.1Q VLAN window, click the VLAN List Tab at
DAS-3626 VDSL2 Switch User Manual Parameter DescriptionVID Allows the entry of a VLAN ID, or displays the VLAN ID of an existi
DAS-3626 VDSL2 Switch User Manual To create a VLAN Batch entry click the VLAN Batch Settings tab at the top of the screen which will display the fol
DAS-3626 VDSL2 Switch User Manual 802.1v Protocol VLAN802.1v Protocol Group SettingsThe table allows the user to create Protocol VLAN groups and add p
DAS-3626 VDSL2 Switch User Manual Figure 131. Protocol VLAN Settings menuThe following fields can be set:Parameter DescriptionGrou
DAS-3626 VDSL2 Switch User Manual Section 10SecuritySafeguard EngineTrusted HostPort SecurityMAC Spoofing AccessAuthentication Control109
DAS-3626 VDSL2 Switch User Manual System Tools MenusThe Tools drop-down menu includes links Configuration File Backup & Restore
DAS-3626 VDSL2 Switch User Manual Safeguard EnginePeriodically, malicious hosts on the network will attack the switch by utilizing packet flooding (AR
DAS-3626 VDSL2 Switch User Manual To view this window, click Security > Safeguard Engine as shown below:Figure 133. Safeguard Engine menuTo configu
DAS-3626 VDSL2 Switch User Manual Port SecurityPort Security Port SettingsA given ports’ (or a range of ports') dynamic MAC address learning can
DAS-3626 VDSL2 Switch User Manual Access Authentication ControlThe TACACS/XTACACS/TACACS+/RADIUS commands allow users to secure access
DAS-3626 VDSL2 Switch User Manual Authentication Policy SettingsThis command will enable an administrator-defined authentication policy for users tryi
DAS-3626 VDSL2 Switch User Manual The following parameters can be set:Parameter DescriptionApplication Lists the configuration app
DAS-3626 VDSL2 Switch User Manual Figure 139. Authentication Server Group Settings Edit menuTo add an Authentication Server Host to the list, enter i
DAS-3626 VDSL2 Switch User Manual Configure the following parameters to add an Authentication Server Host:Parameter DescriptionIP Ad
DAS-3626 VDSL2 Switch User Manual 5 - Login Method Lists menuThe switch contains one Method List that is set and cannot be removed, yet can be modif
DAS-3626 VDSL2 Switch User Manual NOTE: To set the Local Enable Password, see the next section, entitled Local Enable Password.To view the following
DAS-3626 VDSL2 Switch User Manual ResetThe Reset function has several options when resetting the switch. Some of the current configuration parameters
DAS-3626 VDSL2 Switch User Manual Local Enable Password SettingsThis window will configure the locally enabled password for the Enable Admin command.
DAS-3626 VDSL2 Switch User Manual RADIUS Accounting SettingsThe Accounting feature of the switch uses a remote RADIUS server to collect information re
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Section 11CPE ManagementCPE Basic InformationCPE Advanced InformationCPE P
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE Basic InformationTo view the CPE Basic Information menu, click CPE Man
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE Advanced InformationTo view the CPE Advanced Information menu, click C
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE WAN SettingsTo view the CPE WAN Settings menu, click CPE Management &g
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE PPPoE SettingsTo view the CPE PPPoE Settings menu, click CPE Managemen
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE LAN SettingsTo view the CPE LAN Settings menu, click CPE Management &g
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE VLAN SettingsTo view the CPE VLAN Settings menu, click CPE Management
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE ProtoVLAN SettingsTo view the CPE Protocol VLAN Settings m
DAS-3626 VDSL2 Switch User Manual Device Information and Quick Configuration LinksThis window contains the main settings for all major functions on th
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE QoS SettingsThe following window will allow the user to configure the
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE FilterTo view the CPE Filter menu, click CPE Management > CPE Filte
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE FDBTo view the CPE FDB Table, click CPE Management > CPE FDB.Figure
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE SNMPTo view the CPE SNMP menu, click CPE Management > CPE SNMP.Sele
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPE Loopback The CPE Loopback menu is used to perform a CPE loopback test.
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Section 12StatusStatus menus are used for monitoring switch and network fu
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual 1 Day ES/SES/UASThis status window allows you to display Downstream/Upstre
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual CPU Utilization The CPU Utilization window displays the percentage of the
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Port UtilizationThe Port Utilization window displays the percentage of the
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Packet PortsThe Web Manager allows various packet statistics to be viewed
DAS-3626 VDSL2 Switch User Manual Section 2System ConfigurationSystem InformationIP SettingsIPv6 Neighbor SettingsSerial Port SettingsWeb SettingsTeln
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual The following fields can be set or viewed:Parameter
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Received (RX)This table displays the RX packets on the switch. To select a
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Time Interval Select the desired setting between 1s and 60s, where &quo
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual UMB_cast (RX)This table displays the UMB_cast RX Packets on the switch. To
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual The following fields may be set or viewed:Parameter
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Transmitted (TX)To select a port to view these statistics for, select the
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual The following fields may be set or viewed:Parameter
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Error PortsThe Web Manager allows port error statistics compiled by the sw
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual The following fields can be set:Parameter Descriptio
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Transmitted (TX)To select a port to view these statistics for, select the
DAS-3626 VDSL2 Switch User Manual System InformationUse the System Information menu to add name, location and administrator contact information. To v
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual The following fields may be set or viewed:Parameter
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual UtilizationMemory UtilizationThis window is used to display the utilizatio
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Ping TestPing is a small program that sends ICMP Echo packets to the IPv6
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Firmware InformationThe following screen allows the user to view informati
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Section 13MaintenanceFirmware UpgradeConfiguration File Backup & Resto
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual SNMP SettingsSimple Network Management Protocol (SNMP) is an
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual SNMP settings are configured using the menus located on the SNMP V3 folder
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual SNMP Group TableAn SNMP Group created with this table maps SNMP users (ide
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual SNMP User Table This window displays all of the SNMP User's currently
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual To implement changes made, click Apply. To delete an existing SNMP User
DAS-3626 VDSL2 Switch User Manual The following parameters can be configured:Parameter DescriptionInterface Name Displays the interface
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual SNMP Host TableThe SNMP Host Table window is used to set up SNMP trap reci
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual The following parameters can be configured:Parameter
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual SNMP Trap ConfigurationThe following window is used to enable and disable
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Appendix ASystem Log EntriesThe following table lists all possible entries
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual <username>)Interface Port link up Port <portNum> link up, &l
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual SSH Successful login through SSH Successful login through SSH (Username:
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Successful login through SSH authenticated by AAA local methodSuccessful l
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual <username>, MAC: <macaddr>)Successful login through SSH authen
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Successful Enable Admin through Console authenticated by AAA serverSuccess
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Login failed through Telnet from user due to AAA server timeout or imprope
DAS-3626 VDSL2 Switch User Manual IPv6 Neighbor SettingsThis window allows the user to create and configure IPv6 Neighbor settings on the switch. The
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Loop-back DetectionLBD loop occurred Port <portNum> LBD loop occurre
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Port %d SFP %s exceeded the %s warning threshold WarningIP and Password Ch
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual Aged out MAC-AC host aged out (MAC: <macaddr>, port: <portNum>
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual 1.3.6.1.4.1.171.12.11.2.2.3.0.1 MIBswFanRecover1.3.6.1.4.1.171.12.11.2.2.3
Appendix BGlossary1000BASE-SX: A short laser wavelength on multimode fiber optic cable for a maximum length of 500 meters1000BASE-LX: A long wavelengt
LAN - Local Area Network: A network of connected computing resources (such as PCs, printers, servers) covering a relatively small geographic area (usu
Appendix CPassword Recovery ProcedureThis section describes the procedure for resetting passwords on D-Link switches. Authenticating any user who trie
Command Parametersshow account The show account command displays all previously created accounts. 177
DAS-3626 VDSL2 Switch User Manual Serial Port SettingUse the Serial Port Setting window to console serial port setting, config Baud Rate and Auto Logo
DAS-3626 VDSL2 Switch User Manual System Time and SNTP SettingsSimple Network Time Protocol Settings used to set system time are configured in two men
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual __________________________________________________________________________
DAS-3626 VDSL2 Switch User Manual Time Zone SettingsThe following window is used to configure time zones and Daylight Savings time settings for SNTP.
DAS-3626 VDSL2 Switch User Manual DST Repeating Settings Using repeating mode will enable DST seasonal time adjustment. Repeating mode requires that t
DAS-3626 VDSL2 Switch User Manual User Account SettingsThe User Accounts menu is used to control user privileges, create new users and view existing U
DAS-3626 VDSL2 Switch User Manual Figure 25. User Accounts menuEnter the Old Password for the account, the New Password you wish to use, and retype th
DAS-3626 VDSL2 Switch User Manual System Log ConfigurationThis section contains information for configuring various attributes and properties for
DAS-3626 VDSL2 Switch User Manual The following parameters can be set:Parameter DescriptionServer ID Syslog server settings index
DAS-3626 VDSL2 Switch User Manual Section 3Switch ConfigurationMAC Address Aging TimeEthernet Settings FDBTraffic Segmentation CLI Paging Port MirrorL
DAS-3626 VDSL2 Switch User Manual MAC Address Aging TimeThis table specifies the length of time a learned MAC Address will remain in the forwa
DAS-3626 VDSL2 Switch User Manual FDBUse the MAC Address Table menu to view or clear entries from the switch's MAC address forwarding data base (
DAS-3626 VDSL2 Switch User Manual Traffic SegmentationTraffic segmentation is used to limit traffic flow from a single port to a group of ports on eit
DAS-3626 VDSL2 Switch User Manual Table of ContentsWeb-based Switch Configuration
DAS-3626 VDSL2 Switch User Manual Port MirrorThe switch allows you to copy frames transmitted and received on a port and redirect the copies to anothe
DAS-3626 VDSL2 Switch User Manual Port TrunkingUnderstanding Port Trunk GroupsPort trunk groups are used to combine a number of ports together to make
DAS-3626 VDSL2 Switch User Manual Configurable options and and display information in the Port Trunking menu include the following:Parameter
DAS-3626 VDSL2 Switch User Manual Loopback Detection SettingsThe Loopback Detection function is used to detect the loop created by a
DAS-3626 VDSL2 Switch User Manual Q-in-Q SettingsThis function allows the user to enable or disable the Q-in-Q function. Q-in-Q is designed for servic
DAS-3626 VDSL2 Switch User Manual GVRP Global SettingsThe GVRP allows interoperability with other switches, so the values of the GVRP timers can be co
DAS-3626 VDSL2 Switch User Manual Figure 40. GVRP Settings menuThe following fields can be set:Parameter DescriptionFrom Port / To
DAS-3626 VDSL2 Switch User Manual DHCP RelayThe DHCP Relay folder contains six windows regarding the DHCP relay functions on the switch. The DHCP menu
DAS-3626 VDSL2 Switch User Manual Configure the following Option 82 settings in the DHCP/BOOTP Global Settins menu:Parameter Descripti
DAS-3626 VDSL2 Switch User Manual DHCP Relay Interface SettingsThis window allows the user to set up a server, by IP address, for relaying DHCP inform
DAS-3626 VDSL2 Switch User Manual PrefaceThe DAS-3626 User Manual is divided into sections that describe the system installation and operating instruc
DAS-3626 VDSL2 Switch User Manual Spanning TreeThis switch supports three versions of the Spanning Tree Protocol; 802.1D-2004 STP compatible,
DAS-3626 VDSL2 Switch User Manual P2P PortA P2P port is also capable of rapid transition. P2P ports may be used to connect to other bridges. Under RST
DAS-3626 VDSL2 Switch User Manual The following parameters can be set:Parameter DescriptionSTP State Use the radio buttons
DAS-3626 VDSL2 Switch User Manual STP Port SettingsThis window is used to configure the STP Port Settings on the Swtich. STP can be set up on a port p
DAS-3626 VDSL2 Switch User Manual The following fields can be set:Parameter DescriptionFrom Port / To Port A consecutive gro
DAS-3626 VDSL2 Switch User Manual Figure 45. MST Configuration Identification menuThe window above contains the following information:Parameter
DAS-3626 VDSL2 Switch User Manual Figure 46. STP Instance Settings menuThe following information can be set: Parameter Descripti
DAS-3626 VDSL2 Switch User Manual The following parameters can be viewed or set:Parameter DescriptionPort Use the drop-down menu to
DAS-3626 VDSL2 Switch User Manual CFMConnectivity Fault Management (CFM) is defined by IEEE 802.1ag, which is a standard for detecting, isolating and
DAS-3626 VDSL2 Switch User Manual CFM MD SettingsThis window is used to configure the CFM CCM PDU forwarding mode on the Switch. By default the CCM me
DAS-3626 VDSL2 Switch User Manual Intended ReadersThe DAS-3626 User Manual Manual contains information for setup and management of the switch. This ma
DAS-3626 VDSL2 Switch User Manual CFM Mep SettingsThis window is used to display the CFM, maintenance intermediate point and continuity check message
DAS-3626 VDSL2 Switch User Manual CFM Loopback SettingsThis window is used to configure the CFM Loopback settings on the Switch.To view this window, c
DAS-3626 VDSL2 Switch User Manual Figure 55. CFM Linktrace menuThe following parameters can be configured:Parameter DescriptionMEP Nam
DAS-3626 VDSL2 Switch User Manual Section 4VDSL ConfigurationVDSL ProfilesVDSL PortsVDSL StatusThe VDSL Configuration section will allow users to adju
DAS-3626 VDSL2 Switch User Manual Figure 57. VDSL Profile menu – EditParameter DescriptionProfile Name Enter a name to define t
DAS-3626 VDSL2 Switch User Manual Parameter DescriptionDownstream/Upstream Target SNR MarginConfigure the target amount of incr
DAS-3626 VDSL2 Switch User Manual VDSL PortsThe following window is used to attach profiles, configured in the VDSL Profiles section, with VDSL lines
DAS-3626 VDSL2 Switch User Manual VDSL Ports ConfigThe following window is used to config vdsl port status and action. Figure 60. VDSL Ports config ta
DAS-3626 VDSL2 Switch User Manual VDSL StatusFigure 62. VDSL Bitmap Status display58
DAS-3626 VDSL2 Switch User Manual Section 5MulticastingIGMP Snooping SettingsIPv4 Multicasting SettingsIPv4 Limited Multicast Range SettingsIPv4 Max M
DAS-3626 VDSL2 Switch User Manual Section 1Web-based Switch ConfigurationIntroduction Out-of-Band Access to System ManagementInterface IP Settings for
DAS-3626 VDSL2 Switch User Manual IGMP Snooping SettingsInternet Group Management Protocol (IGMP) snooping allows the switch to recognize IGMP queries
DAS-3626 VDSL2 Switch User Manual The following fields can be set:Parameter DescriptionVLAN ID This is the VLAN ID that, along with th
DAS-3626 VDSL2 Switch User Manual IGMP Snooping Rate Limit SettingsThis table allows the user to configure the rate of IGMP snooping control packets t
DAS-3626 VDSL2 Switch User Manual IGMP Multicast Group Profile SettingsThis table allows the user to create igmp multicast group profiles and specify
DAS-3626 VDSL2 Switch User Manual IGMP Snooping Multicast VLAN SettingsThis window is used to configure the IGMP Snooping Multicast VLAN settings on t
DAS-3626 VDSL2 Switch User Manual IPv4 Multicast Profile SettingsThe IPv4 Multicast Profile Settings window allows the user to add a profile to whic
DAS-3626 VDSL2 Switch User Manual IPv4 Limited Multicast Range SettingsThe IPv4 Limited Multicast Range Settings enables the user to configure the por
DAS-3626 VDSL2 Switch User Manual MLD Control MessagesThree types of messages are transferred between devices using MLD snooping. These t
DAS-3626 VDSL2 Switch User Manual The following parameters may be viewed or modified:Parameter DescriptionVLAN ID T
DAS-3626 VDSL2 Switch User Manual Figure 78. MLD Snooping Router IP Settings – Modify menuMLD Snooping Rate Limit SettingsThis window is used to confi
DAS-3626 VDSL2 Switch User Manual Interface IP Settings for Switch Management The switch maintains two IP interfaces used for management, one in-band
DAS-3626 VDSL2 Switch User Manual Figure 80. MLD Snooping Rate Limit Settings – Edit menuEnter the new rate limit and click Apply.MLD Snooping Static
DAS-3626 VDSL2 Switch User Manual MLD Multicast Group Profile SettingsThis table allows the user to create MLD multicast group profiles and specify mu
DAS-3626 VDSL2 Switch User Manual The following fields can be set:Parameter DescriptionVLAN Name This is the VLAN Name that, along wit
DAS-3626 VDSL2 Switch User Manual Multicast Filtering ModeThis table is used to configure the Multicast Filtering settings on the switch. It allows us
DAS-3626 VDSL2 Switch User Manual Section 6Storm ControlOn a computer network, packets such as Multicast packets and Broadcast packets continually flo
DAS-3626 VDSL2 Switch User Manual The following parameters can be configured:Traffic Control SettingsFrom Port / To Port A consecutive group of ports
DAS-3626 VDSL2 Switch User Manual Section 7QoSHOL Blocking PeventionBandwidth ControlTraffic Control802.1p Default Priority802.1p User PriorityQoS Sch
DAS-3626 VDSL2 Switch User Manual Advantages of QoSQoS is an implementation of the IEEE 802.1p standard that allows network administrators a method of
DAS-3626 VDSL2 Switch User Manual G10, H6 ~ H10For weighted round robin queuing, if each CoS queue has the same weight value, then each CoS queue has
DAS-3626 VDSL2 Switch User Manual 802.1p Default PriorityThe switch allows the assignment of a default 802.1p priority to each port on the switch. To
DAS-3626 VDSL2 Switch User Manual Login to Web ManagerTo use the web-based management module for switch management, run the browser you have installed
DAS-3626 VDSL2 Switch User Manual QoS Scheduling MechanismChanging the output scheduling used for the hardware queues in the switch can customize QoS.
DAS-3626 VDSL2 Switch User Manual Figure 92. QoS SchedulingThe following parameters can be configured:Parameter DescriptionFrom
DAS-3626 VDSL2 Switch User Manual In Band Manage SettingsThis window allows the user to specify a priority handling of untagged in-band management pac
DAS-3626 VDSL2 Switch User Manual The following parameters may be set:Parameter DescriptionFrom port / To port A consecutive group of
DAS-3626 VDSL2 Switch User Manual Section 8ACLACL Configuration WizardAccess Profile ListCPU Access Profile ListACL FinderACL Flow MeterAccess profile
DAS-3626 VDSL2 Switch User Manual The following parameters can be configured. Parameter DescriptionType Select the type of ACL y
DAS-3626 VDSL2 Switch User Manual To add an ACL Profile, click the Add ACL Profile button, which, will display the window below. There are four Access
DAS-3626 VDSL2 Switch User Manual The following parameters can be configured. Parameter DescriptionEthernet ACL To configure thi
DAS-3626 VDSL2 Switch User Manual Figure 102. Access Profile Details (Ethernet)To return to the Access Profile List click Show All Profiles, to add a
DAS-3626 VDSL2 Switch User Manual To set the Access Rule for Ethernet, adjust the following parameters and click Apply.Parameter Descr
DAS-3626 VDSL2 Switch User Manual Web-based User InterfaceThe user interface provides access to various switch configuration and management windows, a
DAS-3626 VDSL2 Switch User Manual Figure 104. Access Rule List (Ethernet)To view the configurations for previously configured rules click on the corr
DAS-3626 VDSL2 Switch User Manual Parameter DescriptionVLAN Selecting this option instructs the switch to examine the VLAN part
DAS-3626 VDSL2 Switch User Manual Click Create to view the new Access Profile List entry in the Access Profile List table shown below. To add another
DAS-3626 VDSL2 Switch User Manual The following parameters may be configured for the IP (IPv4) filter.Parameter DescriptionAcce
DAS-3626 VDSL2 Switch User Manual Figure 111. Access Rule Detail InformationTo configure the IPv6 ACL select IPv6 in the Add ACL Profile window, ente
DAS-3626 VDSL2 Switch User Manual The following parameters can be set, for IPv6:Parameter DescriptionIPv6 Class Ticking this ch
DAS-3626 VDSL2 Switch User Manual Figure 114. Access Profile Details (IPv6)To return to the CPU Access Profile List click Show All Profiles, to add a
DAS-3626 VDSL2 Switch User Manual The following parameters may be configured for the IP (IPv6) filter.Parameter DescriptionAcce
DAS-3626 VDSL2 Switch User Manual Figure 117. Access Rule Detail Inforamtion (IPv6)To configure the Packet Content ACL select Packet Content in the A
DAS-3626 VDSL2 Switch User Manual The following parameters can be set, for Packet Content:Parameter DescriptionChunk Allows users to ex
Kommentare zu diesen Handbüchern