DI-2000 Series Routers hardware installation manual
Operating temperature
0℃ to 40℃
Nonoperating temperature
-20℃ to 65℃
Operating relative humidity
10% to 85% noncondensing
Nonoperating relative humidity
5% to 95% noncondensing
Power
Input voltage:170 to 264 V;input frenquency :47
to 63Hz;input current: 0.2A/230V
Power dissipation
28W
Notice
:
Protocols with * are supported only in system Console status.
2.3 Port Connection Specification
The DI-2004 router has two serial ports and one Ethernet port.
2.3.1 PIN description of each port on the DI-2004
1. The Serial Ports of the DI-2004 Router
The DI-2004 router has two serial ports. The jacks are three rows, 44 pins and high
density. The ports have the same PIN description. They can be deployed to be
synchronous or asynchronous methods, so they can connect to synchronous
MODEM(such as TAINET T-1496) or asynchronous MODEM(such as 3Com USR) for
entering special network. For synchronous method, the DI-2004 router also support
the physical protocol of V.35, capable of connecting to baseband MODEM(such as
ASCOM AM64000A ) with a maximum speed of 2Mbps to achieve the high-speed
access goal.
PIN Description of Serial Ports on the DI-2004 is shown as the following table:(PIN in
the table and figure is signed on corresponding location of the jack)
Table 2-3 PIN Description of Serial Ports
PIN Name Symbol Comment
1 Receive Clock RCLK Used for choosing V.28 or v.35
2 Transmit Clock TCLK Used for choosing V.28 or v.35
3 Transmit Data J_TXD
DTE→DCE; used for V.28
4 Receive Data J_RXD
DTE←DCE; used for V.28
5 Output Clock CLK232
DTE→DCE; used for V.28
6 Data Set Ready J_DSR
DTE←DCE; used for both V.28 and V.35
7 Clear To Send J_CTS
DTE←DCE; used for both V.28 and V.35
8 Transmit Clock (negative) TXC-
DTE←DCE; used for V.35
10 Receive Clock(negative) RXC-
DTE←DCE; used for V.35
- 9 -