CONFIGURATION VARIABLES
Configuration Variables control the way the DSA functions. The Variables are assigned to one of several
groups: SCAN, CALIBRATION, IDENTIFICATION, PRESSURE, and DEBUG. Each variable is assigned a
“data type” description.
SCAN VARIABLES
VARIABLE A V G
VALID VALUES 1 to 240
DEFAULT VALUE 16
DATA TYPE integer
DESCRIPTION This sets the number of raw samples to acquire before producing a filtered
output.
VARIABLE B I N
VALID VALUES 1 or 0
DEFAULT VALUE 1
DATA TYPE integer
DESCRIPTION Sets the format of the data packet output.
1 = Binary
0 = ASCII
VARIABLE CVTUNIT
VALID VALUES any real number
DEFAULT VALUE 1.0
DATA TYPE float
DESCRIPTION Unit conversion factor. This converts the calibrated units to the requested
scan units. This value can be set directly or by setting the UNITSCAN
variable to the desired unit.
CVTUNIT will be set whenever UNITSCAN is set. It may be set
independently without setting UNITSCAN. If a user wants to have CVTUNIT
set to a different variable from UNITSCAN, UNITSCAN must be set first.
VARIABLE E U
VALID VALUES 0 or 1
DEFAULT VALUE 1
DATA TYPE string
DESCRIPTION Sets the output format for temperature and pressure units.
0 = raw units
1 = Engineering units
NOTE The module will output 999999 when one or more of the following conditions
exist:
1. The EU conversion exceeds the setting of PMAXL or PMAXH
2. The calculated temperature of any sensor is 79 degrees C or
greater.
The module will output -999999 when one or more of the following
conditions exist:
1. The EU conversion exceeds the setting of PMINL or PMINH
2. The calculated temperature of any sensor is 79 degrees C or
greater.